Below is a list of FANUC servo amplifier alarms and faults with a short description briefly describing the source of each error code.

Blinking "-". Keep the cable on the Servo Amplifier side connected. Overcurrent flowed into the input of the main circuit. Input supply voltage imbalance, IGBT defective. The main circuit power module IPM has detected an overload, overcurrent, or control supply voltage decrease, overcurrent, or control supply voltage decrease.

Internal cooling circuit failure, Overload, Input supply voltage imbalance, IPM failure, or control supply voltage decrease of the power module. Regenerative discharge energy is too high. The input power supply is abnormal open phase or the main circuit capacitor was not recharged within the specified time. When the absolute pulse coder is used, the motor has not yet rotated through more than one turn after the first power—up.

When the magnetic contactor is turned on, the phase sequence of the power supply cannot be determined.

No LED. A first to third reference position return cannot be executed because the reference position has not yet been established. The n—th axis axis 1—8 overload signal is on. Refer to diagnostic display No. Position control system fault. Due to an NC or servo system fault in the reference position return, there is the possibility that reference position return could not be executed correctly.

Try again from the manual reference position return. Abnormal servo motor load has been detected. Alternatively, abnormal spindle motor load has been detected in Cs mode. The position deviation value when the n—th axis axis 1—8 stops is larger than the set value.

The position deviation value when the n—th axis axis 1—8 moves is larger than the set value.Please contact us if you need testing, a repair or an exchange part. Note: Alarm in background edit is displayed in the key input line of the background edit screen instead of the ordinary alarm screen and is resettable by any of the MDI key operation.

Servo Alarms. Beta series SVU: Overhead occured. PSM: Phase missing occured in the input voltage. SVM: The motor current is too high. Beta series. The motor current is too high. Beta serie SVU: The link voltage is too high. PSMR: The regeneration discharge amount is too large.

Alpha series SVU: The regeneration discharge amount is too large. Alternatively, the regeneration discharge ciruit is abnormal. The spare discharge circuit of the DC link is abnormal. Alpha series SVU: The dynamic brake cicruit is abnormal. PSM: The internal stirring fan failed. Beta series SVU: The internal stirring fan failed.

Fanuc 16i/18i/21i

The possible causes are as follows:. A low voltage alarm was issued by the amplifier. Necessary cookies are absolutely essential for the website to function properly. This category only includes cookies that ensures basic functionalities and security features of the website.

Me7 1 bench harness

These cookies do not store any personal information. Failure in data transmission. Failure in Data transmission. Due to an NC or servo system fault in the reference positon return, there is a possibility that the reference position return could not be executed properly. Alternatively, abnormal spindle motor load has been detected in Cs mode. The value set in Parameter NO. A proper value or is not set in parameter No. Illegal data a value below 0, etc was set in parameter No.

Illegal data a value below 0 etc was set in parameter No. Parameters No. PSM : Overheat occured. PSM: Phase missing occured in the input voltage 2. PMSR: The control power supply voltage has dropped. SVM: The motor current is too high 2. Alpha series: The motor current is too high. PSMR: The internal stirring fan failed. The possible causes are as follows: 1. The FSSB communication cable was disconnected or broken.As a generic name for a plain-text language in which CNC machine are able to understand, G-Codes are important to understand in the manufacturing, automation and engineering spaces.

In the factory automation space, nobody likes downtime and receiving error codes.

ROBOCUT models

By definition, a G Code is a computer code language that is used to guide CNC machine devices to perform specific motions. Also referred to as a fixed cycle, canned cycles are ways to effectively and efficiently perform repetitive CNC machining operations. They automate specific machining functions. To learn more about canned cycles, check out this article courtesy of zero-divide.

G-Code is the most popular programming language used for programming CNC machinery. Some G words alter the state of the machine so that it changes from cutting straight lines to cutting arcs.

Other G words cause the interpretation of numbers as millimeters rather than inches. Some G words set or remove tool length or diameter offsets. We also offer repair pricing.

Listed below are some easily-understood G-code commands in which are used for setting the speed, feed, and tool parameters. Keep in mind, the machine operates at the specified speed rate when G1 is used, G1 commands are set to operate at the set F value.

Here is an example:. The Spindle speed is almost always set in RPMs revolutions per minute.

fanuc 2017 alarm

By having up-to-speed knowledge of CNC codes, you could most definitely set yourself apart from the average Joe. He was wondering what the different codes stood for, so we wanted to go ahead and list the different alarm codes for this series. These codes apply to power supplies that start with the following prefixes. The first is if you can visibly look at the end of the shaft and see the holes on the end of the coupling.

Nursery kids polycotton fabric easter farm animal sheep

If your shaft has one hole at the end in the very center, it is a slick shaft. If the shaft has three holes in a line, that means you have a keyed shaft. Your motor may have one of two types of labels on it, the first being a yellow FANUC sticker and the other being a silver G. FANUC sticker. All of the silver G. FANUC stickers on motors have a suffix indicating a keyed shaft, except for the tag which indicates that it is actually a slick shaft.

The pictures below show what each tag looks like with the tag.

Sig sauer mcx power upgrade

If the part number has the tag at the end of it, it is a keyed shaft. If there is no at the end of the part number, that means it is a slick shaft. Be sure to check out our article focused on maintaining automation machine tools.Thanks for visiting our Fanuc Alarm Code and Error page. Necessary cookies are absolutely essential for the website to function properly.

This category only includes cookies that ensures basic functionalities and security features of the website. These cookies do not store any personal information. This website uses cookies to improve your experience.

fanuc 2017 alarm

We'll assume you're ok with this, but you can opt-out if you wish. Accept Reject Read More. Close Privacy Overview This website uses cookies to improve your experience while you navigate through the website. Out of these cookies, the cookies that are categorized as necessary are stored on your browser as they are as essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website.

These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may have an effect on your browsing experience. Necessary Always Enabled.Download Datasheet. Customer Satisfaction Survey Register your product.

Industrial automation Your industry, our expertise Industrial applications For every need, we have a suitable application Customer Cases.

App nao instala ios

Facebook Linkedin Youtube. Spanish English French. German English. Russian English. Dutch English French. English Russian.

Safety EXTERNAL input (disabling on Fanuc controller)

Bulgarian English. Czech English. French English. Hungarian English. Italian English. Russian Turkish English. English French Dutch.

Clone hero drums

Romanian English. Slovenian English.

fanuc 2017 alarm

Dutch English. Polish English. Portuguese English. Slovak English. Spanish English.What is the proper method to test a motor for a short? The proper way to test a FANUC motor for a short is to first lock out the machine, remove the cable from the drive, and test all three motor phases to ground with a megohmmeter. This will test both the motor and the cable for problems. There are a number of explanations for these errors.

However, the RS cable is also another high-fail item. Ensure that you are using a cable that is known to be functional when communicating. Otherwise when you attempt to read-in or punch-out a cable, you will get an alarm that is going to indicate that the cable is incorrect, or that the port has failed.

To test whether the cable or the port has failed, take a known good cable and insert it into the RS port.

Amd hdmi scaling not working

Next, set your machine up to receive a file. Next, transmit your file into the machine tool. These boards or your machine will need to be sent in for repair. What is an Axis Communications Error? What is an Excess Error Alarm and why is it caused? Generally, an Excess Error means that the machine has moved beyond its allowable tolerance.

As the machine moves, there will be some deviation. This deviation is known as the Excess. These errors can be caused by a variety of problems. For example, a dull tool can caused the axis to be pushed out of position which results in a deviation error. Debris build up can cause deviations while the machine is stopped.

Additionally, a failed servo drive can also cause deviation errors. Alarm is a very generic alarm. The CNC, which is in charge of the servos, tells the servo drives to turn on and remain on.

If for whatever reason the servo drive turns itself off without the permission from the CNC, the CNC will generate a alarm. This alarm will usually occur with other alarms, such as the Alarm. The Alarm is an alarm issued by the CNC that says a problem has been found in either the servo drive or the feedback system.

The alarm will show which axis is causing the problem. To identify the specifics of this alarm, you must go into the CNC diagnostics page.Go straight to FANUC Alarm Video When a robot system goes down the first thing the operator wants to do is quickly find out what is wrong and get the system back to work.

The teach pendant displays a variety of robot information. Each new controller model that FANUC releases offers more options for troubleshooting and customizing the information that you can view about your robot.

Active Alarms — Displays the active alarms for the system. There is a fault code displayed for each alarm.

fanuc 2017 alarm

Alarm History — Displays the last alarms. The history helps with troubleshooting the root cause of errors. By analyzing the alarms in the history, you can see if one error triggers multiple other errors. By seeing which error occurred first, you determine if fixing that error solves the other faults. Alarm Descriptions and Remedies — When you select the fault code shown on the alarm log, you will get an Alarm description showing causes and remedies.

This will help you to solve the problem or error and get the system back up and running. Alarm Reports — Available on the new RiB Plus controller is a graph showing the 5 most common faults that have occurred on your system. This is great for troubleshooting and dashboarding. This How-to Video shows how to navigate to each Alarm area on the teach pendant and then use the information to clear faults.

This takes you to the Active Alarm screen where you can see all the alarms that are triggered when the E-stop on the teach pendant is hit. For this fault it reads:. Motion Controls Robotics,….

When deciding on a…. Watch More How-to Videos. Receive New Articles Every Wednesday. Search by Categories. Upcoming Events No upcoming events. Read More Articles. Sandusky County Pride! Each year new robot shipments in North America are breaking records. In the first three…. It is hard to believe, but the end of is here. This year has…. FANUC has released new robot models in several of their robot series. These models were…. The Importance of Robot Integration Services.


thoughts on “Fanuc 2017 alarm”

Leave a Reply

Your email address will not be published. Required fields are marked *